化工儀器網(wǎng)>產(chǎn)品展廳>醫(yī)療器械設(shè)備>血液學(xué)分析設(shè)備>流式細(xì)胞儀>flocel bloodbrain barrier 體外血腦屏障模型裝置-體外3D細(xì)胞屏障培養(yǎng)

flocel bloodbrain barrier 體外血腦屏障模型裝置-體外3D細(xì)胞屏障培養(yǎng)

參考價 211
訂貨量 ≥1
具體成交價以合同協(xié)議為準(zhǔn)

聯(lián)系方式:李勝亮查看聯(lián)系方式

聯(lián)系我們時請說明是化工儀器網(wǎng)上看到的信息,謝謝!


世聯(lián)博研(北京)科技有限公司(Bio Excellence International Tech Co.,Ltd)簡稱為世聯(lián)博研,。世聯(lián)博研是一家集進(jìn)口科研儀器代理銷售以及實(shí)驗(yàn)技術(shù)服務(wù)于一體的技術(shù)公司。世聯(lián)博研專注生物力學(xué)和3D生物打印前沿科研設(shè)備代理銷售及科研實(shí)驗(yàn)項(xiàng)目合作服務(wù),,內(nèi)容涵蓋了血管力學(xué)生物學(xué),、生物力學(xué)建模仿真與應(yīng)用、細(xì)胞分子生物力學(xué),、組織修復(fù)生物力學(xué)、骨與關(guān)節(jié)生物力學(xué),、口腔力學(xué)生物學(xué),、眼耳鼻咽喉生物力學(xué)、康復(fù)工程生物力學(xué),、生物材料力學(xué)與仿生學(xué),、人體運(yùn)動生物力學(xué)等生物力學(xué)研究以及生物材料打印,、打印樣品生物力學(xué)性能測試分析的前沿領(lǐng)域科研利器和科研服務(wù)。

世聯(lián)博研的客戶范圍:
科研院所單位,、生物醫(yī)學(xué)科研高校,、醫(yī)院基礎(chǔ)科研單位等。

世聯(lián)博研公司代理的品牌具有:
1)近10年長期穩(wěn)定的貨源
2)以生物力學(xué),、細(xì)胞力學(xué),、細(xì)胞生物分子學(xué)、生物醫(yī)學(xué)組織工程,、生物材料學(xué)為主,,兼顧其他相關(guān)產(chǎn)品線
3)提供專業(yè)產(chǎn)品培訓(xùn)和銷售培訓(xùn)
4)良好的技術(shù)支持
5)已成交老客戶考證
6)每年新增的貨源。

細(xì)胞應(yīng)力加載儀,3細(xì)胞打印機(jī),NanoTweezer新型激光光鑷系統(tǒng),PicoTwist磁鑷,美國NeuroIndx品牌Kuiqpick單細(xì)胞捕獲切割系統(tǒng)

產(chǎn)地類別 進(jìn)口 產(chǎn)品種類 細(xì)胞分析系統(tǒng)
價格區(qū)間 面議 應(yīng)用領(lǐng)域 醫(yī)療衛(wèi)生,食品/農(nóng)產(chǎn)品,化工,生物產(chǎn)業(yè),農(nóng)林牧漁

體外血腦屏障模型裝置-體外3D細(xì)胞屏障培養(yǎng)

flocel體外血腦屏障實(shí)驗(yàn)?zāi)P拖到y(tǒng)

flocel體外血腦屏障實(shí)驗(yàn)?zāi)P拖到y(tǒng)是Flocel公司生產(chǎn)和銷售的一個更實(shí)際的,、動態(tài)的體外血腦屏障(DIV-BBB™)模型,,更準(zhǔn)確地反映真正的血腦屏障特性。

—Flocel體外三維動態(tài)血腦屏障(Dynamic In Vitro Blood-Brain Barrier Model)

Blood-Brain Barrier Model)

體外血腦屏障測量模型一般包括:

1)跨細(xì)胞膜電阻測量(TEER 檢測)系統(tǒng)

2)計(jì)算機(jī)控制的脈動泵

3)flocel控制軟件

是Flocel公司生產(chǎn)和銷售的一個更實(shí)際的,、動態(tài)的體外血腦屏障(DIV-BBB™)模型,,更準(zhǔn)確地反映真正的血腦屏障特性。

迄今為止,,研究者已經(jīng)使用靜態(tài)BBB模型或動物模型進(jìn)行了測試,。和這些方法對比,flocel的DIV-BBB模型的優(yōu)勢:

 

更的藥代動力學(xué)和毒理學(xué)研究

● 更準(zhǔn)確地反映體內(nèi)血腦屏障特性

● 模仿重要的內(nèi)皮細(xì)胞-星形膠質(zhì)細(xì)胞相互作用

● 電測量血腦屏障的完整性

● 能使用真實(shí)的人體細(xì)胞

● 形成比現(xiàn)有靜態(tài)模型更緊密的連接

● 可大幅降低藥物開發(fā)成本

特點(diǎn)

與傳統(tǒng)血腦屏障系統(tǒng)相比,,F(xiàn)locel體外動態(tài)血腦屏障系統(tǒng)模型特點(diǎn)如下:

  • 可以做更準(zhǔn)確的藥代動力學(xué)和毒物學(xué)的研究

  • 更清楚準(zhǔn)確的反應(yīng)了體內(nèi)血腦屏障的特性

  • 模擬重要的內(nèi)皮細(xì)胞與星形膠質(zhì)細(xì)胞之間的作用

  • 用電力方法檢測了血腦屏障的完整性

  • 可以用真實(shí)的細(xì)胞做實(shí)驗(yàn)

  • 比現(xiàn)存的靜態(tài)模型更能形成緊密的連接

  • 降低藥物研發(fā)的成本

1.DIV-BBB 管腔

特性

優(yōu)點(diǎn)

可控制腔內(nèi)/非腔體積比

體型小,,僅175px長

電極與管腔一體化

成本低

與體內(nèi)體積比相符

減少了試驗(yàn)所需細(xì)胞數(shù)目

TEER檢測系統(tǒng)操作簡單

一次性使用,不能重復(fù)使用

動態(tài)血腦屏障參數(shù)動態(tài)血腦屏障參數(shù)

2.跨細(xì)胞膜電阻測量(TEER 檢測)系統(tǒng)

TEER檢測系統(tǒng)為研發(fā)人員提供了一個快速,、簡便地評估血腦屏障完整性方法,,此外,電阻抗值(>1000 Ω-cm)也非常接近體內(nèi)數(shù)值,。TEER檢測系統(tǒng)同時配帶了所需檢測軟件,、電線和襯板,可供4個DIV-BBB管腔同時使用,。其中檢測軟件可以自定義設(shè)置泵的流速,、頻率、波形等參數(shù),。其它特性及優(yōu)點(diǎn)見下表:

特性

優(yōu)點(diǎn)

多頻率下檢測電阻抗

描述電極的電阻和電容

低電壓,,Max=60毫伏

限制對屏障的潛在破壞作用

自動檢測多個管腔

可同時連接4個盒子

檢測軟件可自定義設(shè)置泵的流速、頻率,、波形等參數(shù)

檢測電阻抗,,記錄數(shù)據(jù)

USB連接

臺式或者便攜式電腦均可連接

- Transcending the Transwell -

 

  

______________________________________

 

 

 

  

"...the exposure to intraluminal flow plays an essential role in promoting endothelial cell differentiation and increasing BBB tightness..."

 

"...in contrast to the Transwell apparatus...endothelial cells grown under dynamic conditions ...develop in a monolayer fashion, thus mimicking the structural physiology of capillaries in vivo..."

 

Side by side comparison between dynamic versus static models
of blood–brain barrier in vitro: A permeability study

Janigro et al., 2006

 

 

  

______________________________________

 

  

 

  

   

Our mission at Flocel Inc. is not only to to provide high-quality products and services for in vitro 3D cell barrier culture, but also to convey -with integrity and transparency- the advantages of our DIV-BBB 2.0 system compared to other approaches --such as the Transwell.

 

 

 

 

 

                               

- Stronger Barriers, Stronger Data -

 

 

  

A comparative study between cell barriers cultured in a static flow (i.e., Transwell) and dynamic flow (i.e., DIV-BBB) environment showed that fluid flow conditions greatly influence how a cell barrier develops. Trans-endothelial electrical resistance (TEER) across the DIV-BBB culture (B) increased to values 10-fold higher than those recorded in the Transwell (A), and much closer to values observed in vivo. This is because dynamic flow causes shear stress on the apical surface of the cell, and influences cell development and function.

 

This concept is reiterated in the inset microscope images of the figure above: A cell culture that has been subjected to dynamic flow and physiologically-representative levels of shear stress (B) resulted in a confluent monolayer of cells expressing tight junctions. The cell barrier in under static flow (A) receives no shear stress, and instead forms a multilayer of cells with less tight junction organization.

 

 

 

       

   

- Higher Selective Permeability -

 

 

    

 

 

 

   

Owing to the stronger and more physiologically-accurate cell barrier grown under dynamic flow conditions, the DIV-BBB also presents a more stringent regulation of selective permeability. Tests conducted between cells cultured in the DIV-BBB (C) and Transwell (D) for passage of phenytoin (an epileptic drug with in vivo permeability levels of 0.0001 cm/s) showed markedly higher levels of permeability through the Transwell than the DIV-BBB, and 4-fold higher than in vivo. The stronger and more physiologically-accurate cell barriers grown under the dynamic fluid conditions of the DIV-BBB allow for more accurate testing of drug permeability and pharmacokinetics.

 

 

 

 

    

- What if I already own Transwell products? -

 

 

 

   

 

 

   

If you would prefer to continue using your Transwell products (such as Endohm-6, Endohm-12, Endohm-24SNAP cell culture chambers or any "chopstick" electrodes), we also offer a Trans-endothelial Electrical Resistance (TEER) Measurement Unit that is compatible with these Endohm products, and much more versatile! Not only does our TEER Measurement Unit allow for frequency sweeps between 0.1 Hz and 1,000 Hz (0.1 Hz sampling resolution), it can be directed by the user to automatically sample single-frequency and frequency sweep data for an indefinite amount of time, and save this data to a .xls or .csv save file. No  more pushing a button and jotting down the TEER value every time you want to take a measurement!

 

 

測試服務(wù)

世聯(lián)博研和Flocel Inc.聯(lián)合,提供以合同為基礎(chǔ)的體外 BBB滲透性測試。費(fèi)用結(jié)構(gòu)由待測化合物的數(shù)量和測試的復(fù)雜性決定,。這項(xiàng)服務(wù)在克利夫蘭基金會,,斯坦福大學(xué)和歐洲的實(shí)驗(yàn)室進(jìn)行。我們還提供腦生物標(biāo)志物的咨詢服務(wù)和測試儀器,,并通過分析外周血檢測人體受試者血腦屏障的完整性,,提供診斷患者或運(yùn)動員血腦屏障的方法。
輕型顱腦損傷(MHI和MTBI)占顱腦損傷的95%,;診斷和早期管理包括計(jì)算機(jī)斷層掃描(CT)或住院觀察,,但是這些選項(xiàng)都不理想。在醫(yī)院觀察是不經(jīng)濟(jì)的,;CT有時是不切實(shí)際的,,涉及潛在的有害電離輻射。GFAP和S100等腦蛋白在體液中表達(dá)水平與許多神經(jīng)系統(tǒng)疾病有關(guān)聯(lián)性,。Flocel開發(fā)了商業(yè)化的血液測試小型工具,,給創(chuàng)傷性腦損傷進(jìn)行前期及時診斷,防止嚴(yán)重的延遲性后果,。

 

發(fā)文獻(xiàn)

 

- Publications -

  • The role of shear stress in blood-brain barrier endothelial physiology.
         Cucullo L, Hossain M, Puvenna V, Marchi N, Janigro D.

  • A dynamic in vitro BBB model for the study of immune cell trafficking into the central nervous system.
         Cucullo L, Marchi N, Hossain M, Janigro D.

  • Pattern of P450 expression at the human blood-brain barrier: roles of epileptic condition and laminar flow.
         Ghosh C, Gonzalez-Martinez J, Hossain M, Cucullo L, Fazio V, Janigro D, Marchi N.

  • Tobacco smoke: a critical etiological factor for vascular impairment at the blood-brain barrier.
         Hossain M, Sathe T, Fazio V, Mazzone P, Weksler B, Janigro D, Rapp E, Cucullo L.

  • Immortalized human brain endothelial cells and flow-based vascular modeling: a marriage of convenience for rational neurovascular studies.
         Cucullo L, Couraud PO, Weksler B, Romero IA, Hossain M, Rapp E, Janigro D.

  • Side by side comparison between dynamic versus static models of blood-brain barrier in vitro: a permeability study.
         Santaguida S, Janigro D, Hossain M, Oby E, Rapp E, Cucullo L.

  • Glycerophosphoinositol and dexamethasone improve transendothelial electrical resistance in an in vitro study of the blood-brain barrier.
         Cucullo L, Hallene K, Dini G, Dal Toso R, Janigro D.

  • A new dynamic in vitro model for the multidimensional study of astrocyte-endothelial cell interactions at the blood-brain barrier.
         Cucullo L, McAllister MS, Kight K, Krizanac-Bengez L, Marroni M, Mayberg MR, Stanness KA, Janigro D.

 

- Posters -

  • A Dynamic Humanized drug resistant In Vitro Blood-Brain Barrier Model to assess the permeability of relevant CNS drugs

  • Development of a novel blood-brain barrier model by coupling Immortalized human brain endothelial cells with flow-based cell culture technologies

  • Glioblastoma Cell Line Metabolism Under Dynamic and Static Conditions: Effects on tumor growth and BBB integrity

  • Humanized in vitro blood-brain barrier models to screen for brain penetration of antiepileptic drugs

  • Effect of Shear stress on BBB endothelial cells: A proteomic study by 2-dimensional protein electrophoresis



化工儀器網(wǎng)

采購商登錄
記住賬號    找回密碼
沒有賬號,?免費(fèi)注冊

提示

×

*您想獲取產(chǎn)品的資料:

以上可多選,,勾選其他,可自行輸入要求

個人信息:

溫馨提示

該企業(yè)已關(guān)閉在線交流功能