西門子數(shù)控系統(tǒng)報警700002故障,,300501:電流量測量回路錯誤,300607:限制電流調(diào)節(jié)器輸出,,300608:限制了轉(zhuǎn)速調(diào)節(jié)器輸出端,,300500:識別驅(qū)動出錯,25201:靜止誤差監(jiān)控,,過流(常見607,、608報警)維修,,,F(xiàn)30005故障維修,,F(xiàn)07930代碼維修,F(xiàn)30897故障維修,,F(xiàn)07801故障維修,,F(xiàn)30027故障維修,25201故障維修,,模塊短路維修,,報警號300501和25201故障,25202故障,,輪廓監(jiān)控故障,,300500,,代碼607,伺服故障,,608故障,,,MX1主動編碼器硬件出錯,,F(xiàn)31111故障維修,,F(xiàn)31412編碼器故障報警維修,207016軸A驅(qū)動4電機溫度傳感器,,231885軸A循環(huán)數(shù)據(jù)傳輸故障,,231897無組件通訊,025030軸A1實際速度誤差報警,,025040禁止誤差監(jiān)控,,21614達到硬件限制,西門子1FT5維修 西門子1FK6維修 西門子1FT6維修 西門子1FK7維修 西門子1PH 維修,,西門子840Dsl系統(tǒng)加工過程中報警230002 207841 25201 21611 ,,每天都出現(xiàn),剛開始懷疑電源模塊有問題,,更換了電源模塊和主軸驅(qū)動,,過了半個月繼續(xù)報警,故障現(xiàn)象NCK上RDY亮紅燈,,RUN亮綠燈,,所有伺服驅(qū)動的RDY和DC-LINK都亮紅燈。干活過程中監(jiān)控R26 都在600V沒有波動,,P210為600,,P1244為765,P1248為435.測量電源模塊電抗器沒有問題,,后來將電源模塊加上了電網(wǎng)識別,,就沒有230002報警了,出來一個201060報警,,就是電源模塊缺少功率部件EP24V,,檢查了電源模塊24V發(fā)現(xiàn)是NCU給出來的,線路都正常,,直接更換了NCU模塊故障解決未發(fā)生報警,,840Dsl 系統(tǒng)報警230002 207841 25201 21611,西門子數(shù)控系統(tǒng)700001報警,,報警的時候監(jiān)控一下PLC程序,,觸發(fā)急停報警的條件除了急停開關(guān)本身,驅(qū)動報警也會觸發(fā)急停報警,,在報警的時候看一下驅(qū)動器上是否有報警,。西門子數(shù)控系統(tǒng)報警700002故障