1070Change of the PWM frequency not possible. PWM frequency change is in progress.無法更改PWM頻率,。PWM頻率更改正在進(jìn)行中,。
包米勒伺服驅(qū)動(dòng)器常見故障維修:
Effect: The new set PWM frequency is not accepted.
影響:不接受新設(shè)置的PWM頻率,。
The error can be caused:
錯(cuò)誤可能由以下原因引起:
1 The previous PWM frequency change is in progress.
上一次PWM頻率更改正在進(jìn)行中,。
Remedy: Reduce the cycle of the PWM change or implement a function into the master control which enables a PWM change only after the previous change was completed.
補(bǔ)救措施:減少PWM更改的周期,,或在主控制中執(zhí)行一項(xiàng)功能,,該功能僅在完成前一次更改后才能啟用PWM更改,。
1 The PWM frequency redurction of the power unit temperature
model is active (warning 216).功率單元溫度的PWM頻率降低
模型處于活動(dòng)狀態(tài)(警告216),。
Remedy: Monitoring of warning 216 via master control. If warning
216 is active no PWM change is initiated.
補(bǔ)救措施:通過主控監(jiān)控警告216,。如果警告216是激活的,沒有啟動(dòng)PWM改變。