鮑米勒伺服驅(qū)動器維修服務(wù):719:Timeout during motor identification電機識別超時,。Error during identification of motor parameters. The maximum permitted phase voltage (= 80 V) was exceeded during the resistance measurement.識別電機參數(shù)時出錯,。在電阻測量過程中,,超過了每個允許相的最大電壓(=80V),。
Possible cause: 原因:
Incorrect motor nominal current setting in Parameter 107.09.
參數(shù)107.09中的電機標(biāo)稱電流設(shè)置不正確,。
Effect: Output voltage set to ZERO to protect the motor. An additional drive block occurs with standard error response.
效果:輸出電壓設(shè)置為零,,以保護電機,。附加的驅(qū)動器塊出現(xiàn)標(biāo)準(zhǔn)錯誤響應(yīng),。
Resetting after error elimination: 錯誤消除后重置:
Error reset is possible. Timeout (45 seconds) with R measurement with motor parameter identification, such as due to error during current / voltage measurement or normalization or limit value.錯誤重置是可能的,。電機參數(shù)識別的R測量超時(45秒),,例如由于電流/電壓測量或標(biāo)準(zhǔn)化或限值過程中的錯誤。
(空格分隔,最多3個,單個標(biāo)簽最多10個字符)