閱讀:378        發(fā)布時(shí)間:2023-8-15

ProSoft PLX31-EIP-MBS模塊

ProSoft PLX31-EIP-MBS模塊





EtherNet/IP to Modbus Serial

PLX31-EIP-MBS

ProSoft Technology’s EtherNet/IP™ to Modbus® Serial communication gateway allows high-speed bi-directional data transfers between EtherNet/IP™ PACs or devices and Modbus®-enabled PACs or devices.

EtherNet/IP™ PACs include Rockwell Automation® ControlLogix® and CompactLogix™, as well as several Schneider Electric® controllers. Modbus® Serial devices are widely used in nearly every industry and include SCADA systems and Power Monitors.

The gateway includes several features that allow for simplified integration, reduced commissioning time and optimized performance

※※※ 深圳市扎克貿(mào)易有限公司

※※※ 張瑞 188-24-24-3080(V同)

※※※ Q:306-167-1820

Specifications

EtherNet/IP™ Specifications 

Specification

Description

Number of Class 3 Server Connections

5

Supported PLC Types

PLC2, PLC5, SLC, CLX, CMPLX, MICROLX

Supported Message Types

PCCC and CIP

Class 3 Client Connections

Connected: 2
Unconnected: 1

Number of Class 1 I/O Connections

2

I/O connection sizes

248/248

Max RPI time

5 ms per connection

CIP Services Supported

0x4C - CIP Data Table Read
0x4D - CIP Data Table Write
CIP Generic

Command List

Support for 100 commands per Client, each configurable for command type, IP address, register to/from addressing and word/bit count.

Command Sets

PLC-2/PLC-3/PLC5 Basic Command Set
PLC5 Binary Command Set
PLC5 ASCII Command Set
SLC500 Command Set

Modbus Serial Specifications 

Specification

Description

Command List

Up to 100 commands per Master port, each fully configurable for Function Code, slave address, register to/from addressing and word/bit count.

Supported Modbus Function Codes

1: Read Coil Status
2: Read Input Status
3: Read Holding Registers
4: Read Input Registers
5: Force (Write) Single Coil
6: Preset (Write) Single Holding Register

15: Force (Write) Multiple Coils
16: Preset (Write) Multiple Holding Registers
22: Mask Write Holding Register (Slave Only)
23: Read/Write Holding Registers (Slave Only)

Software configurable communication parameters

Baud rate: 110 baud to 115.2 kbps Parity: None, Even, Odd Data Size: 7 or 8 bits Stop bits: 1 or 2 RTS on/off delay: 0 to 65535 milliseconds
Modbus RTU mode (binary) with CRC-16
Modbus ASCII mode with LRC error checking
Floating Point Data Floating point data movement supported, including configurable support for Enron and Daniel implementations

Polling of Command List

Configurable polling of command list, including continuous and on change of data, and dynamically user or automatic enabled.

Status Data

Error codes available on an individual command basis. In addition, a slave status list is maintained

Node Address

1 to 247 (software selectable)

RS Interface

RS232, RS422, and RS485

Transmit and Receive Buffer Size

255 byte Transmit character length with 0 to 65535 millisecond delay between each transmitted character