您好, 歡迎來(lái)到化工儀器網(wǎng)! 登錄| 免費(fèi)注冊(cè)| 產(chǎn)品展廳| 收藏商鋪|
當(dāng)前位置:上海薩帛機(jī)電控制系統(tǒng)有限公司>> GWA 2000 Sensor IR ADOS GmbH泄露報(bào)警探測(cè)器進(jìn)口優(yōu)惠銷(xiāo)售
參 考 價(jià) | 面議 |
產(chǎn)品型號(hào)
品 牌
廠商性質(zhì)經(jīng)銷(xiāo)商
所 在 地上海市
更新時(shí)間:2024-05-20 17:49:42瀏覽次數(shù):634次
聯(lián)系我時(shí),請(qǐng)告知來(lái)自 化工儀器網(wǎng)快速報(bào)價(jià)以下ADOS GmbH列表型號(hào)!若您的ADOS GmbH型號(hào)與以下型號(hào)類(lèi)似,或者品牌一樣,,我們都可以為您找到,約1-2個(gè)工作日反饋報(bào)價(jià)!
基于我們與ADOS GmbH廠家備件部門(mén)的長(zhǎng)期通力合作,,以更好的采購(gòu)、更精準(zhǔn)的貨期,、更專(zhuān)業(yè)的服務(wù)態(tài)度為您全天候服務(wù),!
本公司是歐洲工控產(chǎn)品供應(yīng)商,直接源頭采購(gòu)歐洲產(chǎn)地工業(yè)備件,,歐洲工控產(chǎn)品*品質(zhì)歐洲工控產(chǎn)品進(jìn)口原裝歐洲工控產(chǎn)品精確貨期,。
上海薩帛機(jī)電設(shè)備有限公司,價(jià)格優(yōu)勢(shì),!
----------------------------------------------------------
- :彭 -
- 手機(jī):/ -
- :(直線(xiàn)) -
- -
- :[email protected]或者 -
-----------------------------------------------------------
地址:上海浦東新區(qū)外高橋楊高北路536號(hào)樂(lè)非天地大廈6層
公司:www.sahbore,。。com
詢(xún)價(jià)請(qǐng)?zhí)峁ㄆ放?型號(hào)+數(shù)量+公司全稱(chēng)/)或原產(chǎn)品的現(xiàn)場(chǎng)圖片信息,。我們會(huì)盡快做出回復(fù) ,。
優(yōu)價(jià)銷(xiāo)售:
ADOS GWA 2000 Sensor IR 泄露報(bào)警探測(cè)器
ADOS ADOS 592 TOX CL2 0-50PPM 氯氣變送器
ADOS GWA 2000 Sensor IR 泄露報(bào)警探測(cè)器
ADOS ADOS 592 TOX CO 探頭
ADOS GmbH ADOS 592 TOX C0 探頭
Measurement principle: | When combustible or reducing gases are absorbed by the surface of the sensor, the concentration of the test gas is determined by the change in conductivity. |
Measuring ranges: | ppm ranges up to 100% LEL |
Measuring components: | CH4, liquid gas, H2 and many others |
Types of equipment: | GTR 210, GTR 196, GWA 2000 |
Measurement principle: | Measuring the combustion heat at a fixed catalyst |
Measuring ranges: | from a few ppm to Vol% ranges |
Measuring components: | CO, CH4, NH3, C6H6, CnHm, and/or all combustible gases |
Types of equipment: | KM 2000 CnHm EM, GTR 210, GTR 196, GWA 2000, LCTR 903, LCTR 404 LON? |
Measurement principle: | Measuring the different thermal conductivity between test gas and reference gas |
Measuring ranges: | from 0-1 Vol% to 0 - 100 Vol% |
Measuring components: | CO2, H2, He, and many others |
Types of equipment: | GTR 210, GTR 196, GWA 2000 |
Measurement principle: | Measuring the electron flow produced by chemical reaction |
Measuring ranges: | from a few ppm upto Vol% ranges |
Measuring components: | CO, 02, H2S, SO2, Cl2, HCl, NH3, NO, NO2 and many others |
Types of equipment: | TOX 592, GTR 210, GTR 196, GWA 2000 |
Measurement principle: | Non-dispersive infrared analysis |
Measuring ranges: | from 0 - 3000 ppm to 0 - 100 Vol% |
Measuring components: | CO2, CO, liquid gas, CH4, CnHm and many others |
Types of equipment: | ITR 504, GTR 210, GTR 196, LCTR 903 |
Measurement principle: | Chemisorption at semiconductors, Heat reaction, Thermal conductivity, Electro-chemical reaction, Infrared analysis | |
Measuring ranges: | Chemisorption at semiconductors: | ppm ranges to 100 % LEL |
Heat reaction: | from 0-5 Vol% to 0-100 Vol% | |
Thermal conductivity: | from 0-1 Vol% to 0 - 100 Vol% | |
Electro-chemical reaction: | from ppm ranges to Vol% ranges | |
Infrared analysis: | ppm ranges to Vol% ranges | |
Measuring components: | O2, H2, CO2, CO, CH4, hydrogen chloride, helium, neon, propane, toluene, xylene and many others | |
Types of equipment: |
|
Measurement principle: | Electrochemical reaction, infrared analysis |
Measuring ranges: | - 50 Vol% CO2, 0 - 100 Vol% CH4, 0 - 21 Vol% O2, 0-2 Vol% H2; 0-500 ppm ... 0-5000 ppm H2S |
Measuring components: | CH4, H2S, CO2 (optionally continuous) H2S, H2 (only discontinuous) |
Types of equipment: | Biogas 401, Biogas 905 |
Measurement principle: | Non-dispersive infrared analysis |
Measuring ranges: | 0-3000 ppm to 0-100 Vol% |
Measuring components: | CO2 |
Types of equipment: | ITR 504 |
Infrared Gas Analyser System
Continous measurement of gases, that exhibit the properties of absorbing infrared energy (e.g. carbon dioxide) Typically used for the measurement of carbon dioxide over the range of 0–5000 ppm to 0–100 Vol. %.
Processes, in which the moisture content in the gas can be as high as 95% rel. humidity, for example:
The ITR 504 Infrared Gas Analyser System functions on the principle of NDIR technology (non-dispersive infrared). The test gas flows through a measurement chamber that incorporates an IR radiating source and a two-channel infrared detector. The intensity of the infrared radiation is reduced as it passes through the gas molecules. The concentration of the gas can then be calculated by the magnitude of the reduction in intensity.
Since only absorption of the wavelength specific to the gas under test in relation to the wavelength not absorbed by a test gas is considered, interference due to dust, ageing etc., is almost fully compensated. The measured values are temperature-compensated.
Signal horn, warning lamp, warning banner, testmeter, plotter, stand-by power supply UPS 2000-24V.
Further accessories will be offered according to themeasurement tasks required of the system.
Measurement principle: | Non-dispersive infrared analysis |
Measurement range: | 0-3000 ppm to 0-100 Vol% CO2 other measurement ranges available on request |
t90-time: | < 40 sec. |
Overall error: | < ±3 % of range f.s.d. |
Linearity error: | < ±3 % of range f.s.d. |
Long term drift: | < ±5 % of range f.s.d. / month (Zero/Span) |
Ambient temperature: | 14 °F to +113 °F |
Type of protection: | IP 54 |
Supply voltage: | 24 V DC / 115 V AC / 230 V AC (optional) |
Power consumption: | 10 VA |
Outputs: | 3 relay contacts for alarms 1 relay contact, fault 1 relay contact, horn 1 relay contact, warning banner All outputs are floating change-over contacts, maximum rating 250V / 4A Analog output, 4-20 mA Serial interface, RS 232 / RS 485 |
Inputs: | 1 input for cancelling horn signal |
Dimensions (W x H x D): | 9.45 x 6.3 x 3.54 inch |
Weight: | approx. 4.41 lbs |
Measurement principle: | Electrochemical reaction, thermal conductivity |
Measuring ranges: | CO 0-100 ppm CO2 0-20 Vol% O2 0-25 Vol% |
Measuring components: | O2, CO2, CO |
Types of equipment: | Flue Gas Analyzer RG 399 |
Measurement principle: | Non-dispersive infrared analysis |
Measuring ranges: | from 0 - 5000 ppm to 0 - 100 Vol. % |
Measuring components: | CO2, O2 |
Types of equipment: | ITR 498 hand-held unit |
Thermocouples: | Iron copper-nickel Fe-CuNi, nickel-chromium nickel, platinum-rhodium platinum |
Resistance Thermometers: | to DIN standards, with Pt 100 ohm or Ni 100 ohm precision resistors |
pH - Measured Value Transducer: | Flow-through fitting, electrode, impedance transformer, coaxial electrode connection cable, buffer solutions Measuring transducer: ADOS GTR 210 pH or GTR 196 pH Evaluation unit for 8 pH sensors and 8 gas sensors: MWS 906 Sensor, compact |
Accessories: | Balance lines, thimbles, stop flanges, protective sleeves, weiding collars, reference junction thermostats, compensating terminals |
Indicators: | Housing dimensions : 7.6 x 7.6 inch & 5.7 x 2.8 inch |
Recorders: | Single-colour and six-colour dot recorders Single-colour, two-colour and three-colour line recorders |
Counters: | Electric mass flow counters - housing dimensions : 5.7 x 2.8 inch Input signal : 0-(4)-20 mA |
Software: | data collection and visualisation with the software "Log & View" for MWS 903 |
Measuring ranges: | Input signal: from 0-5 mV to 0-100 V, from R = 3 ohm to R = 10 kohm Output signal: load independent current 0-(4)-20 mA |
For connecting: | Remote resistive sensors, resistance thermometers, thermocouples, millivolt sensors, humidity and level sensors. |
Types of equipment : | MS 50 |
Measuring ranges: | Currents of 0-20mA or 4-20mA Voltages from 100 mV to 230 V Resistance from 3 ohm to 10 kohm |
Types of equipment: | GWM 500 |
Measurement principle: | Summation of up to 4 signals from 0-20 mA with conversion to a signal of 0-(4)-20 mA |
Application: | Summation of quantities (flow-through) on a total quantity flow-meter Summation of various heat quantities Cross-sensitivity correction in gas analysis |
For pressure and temperature correction in conjunction with flow-through measurements | |
Measuring ranges: | ±20 % of the temperature setpoint, ±30 % of the pressure setpoint |
Output signal: | 0-(4)-20 mA |