您好, 歡迎來(lái)到化工儀器網(wǎng)! 登錄| 免費(fèi)注冊(cè)| 產(chǎn)品展廳| 收藏商鋪|
當(dāng)前位置:上海薩帛機(jī)電控制系統(tǒng)有限公司>> 60.149.000075 Retsch GmbH進(jìn)口篩網(wǎng)優(yōu)價(jià)銷售
參 考 價(jià) | 面議 |
產(chǎn)品型號(hào)
品 牌
廠商性質(zhì)經(jīng)銷商
所 在 地上海市
更新時(shí)間:2024-05-20 13:07:38瀏覽次數(shù):898次
聯(lián)系我時(shí),,請(qǐng)告知來(lái)自 化工儀器網(wǎng)快速報(bào)價(jià)以下Retsch GmbH列表型號(hào),!若您的Retsch GmbH型號(hào)與以下型號(hào)類似,或者品牌一樣,,我們都可以為您找到,,約1-2個(gè)工作日反饋報(bào)價(jià),!
基于我們與Retsch GmbH廠家備件部門的長(zhǎng)期通力合作,以更好的采購(gòu),、更精準(zhǔn)的貨期,、更專業(yè)的服務(wù)態(tài)度為您全天候服務(wù)!
本公司是歐洲工控產(chǎn)品供應(yīng)商,,直接源頭采購(gòu)歐洲產(chǎn)地工業(yè)備件,,歐洲工控產(chǎn)品*品質(zhì)歐洲工控產(chǎn)品進(jìn)口原裝歐洲工控產(chǎn)品精確貨期。
上海薩帛機(jī)電設(shè)備有限公司,,價(jià)格優(yōu)勢(shì),!
----------------------------------------------------------
- :彭 -
- 手機(jī):/ -
- :(直線) -
- -
- :[email protected]或者 -
-----------------------------------------------------------
地址:上海浦東新區(qū)外高橋楊高北路536號(hào)樂(lè)非天地大廈6層
公司:www.sahbore。,。com
詢價(jià)請(qǐng)?zhí)峁ㄆ放?型號(hào)+數(shù)量+公司全稱/)或原產(chǎn)品的現(xiàn)場(chǎng)圖片信息,。我們會(huì)盡快做出回復(fù) 。
優(yōu)價(jià)銷售:
Retsch 60.149.000075 篩網(wǎng)
Retsch 60.149.000125 篩網(wǎng)
Retsch 60.149.000100 篩網(wǎng)
Retsch 32.662.0001 鎖緊裝置
Retsch 30.018. 0001 主機(jī)
Retsch 60.149.000075 篩網(wǎng)
Retsch 60.149.000125 篩網(wǎng)
Retsch 60.149.000100 篩網(wǎng)
Product Selection
Retsch Technology develops and sells state-of-the-art optical measuring systems for particle characterization based on different measurement techniques:
The most important methods for the characterization of particles in the nanometer and micrometer range are dynamic and static laser light scattering (laser diffraction). The static laser light scattering can be used for the analysis of emulsions, suspensions and dry samples.
Particle Analyzer | Particle Analyzer | |
![]() | ![]() | |
|
| |
Nano Particle Analyzer | ||
![]() | ||
| ||
Contact us
Generate brochure
The particle analyzer LA-960 operates on the basis of static laser light scattering (acc. ISO 13320) and was developed as a solution to customer requirements for a high-performance, flexible, and easy to use instrument for a wide variety of applications - from particle charactarization of powders and granules to the measuring of suspensions and emulsions. It can be ordered in different configurations for
The complete processing time from one sample to the next is only 1 minute, this is only a quarter of the usual time up to now. An integrated system and software automation guarantees simple operation and excellent reproducibility of the measuring results. The measuring cells are located on a movable slide which makes changing the dispersion unit a matter of seconds.
Single range-Samples can be measured over the complete range (0.01 to 5000 μm) without the need to combine different measurements and/or change lenses.
The particle analyzer LA-960 features a powerful circulation system for wet measurements. Thanks to the increased sensitivity small particles with a diameter up to 10 nm are reliably detected. In combination with the evaluation software the system sets new standards regarding precision, speed and resolution.
For dry measurements the effective dispersion unit PowderJet can be used. Thanks to the combination of dry measurement cell with integrated dispersion nozzle and suction mechanism, a great variety of powders can be dispersed and measured quickly and reliably.
Product Advantages
Features
Application examples1 | catalysts, ceramics, chemical-mechanical polishing, cosmetics, foodstuffs, metal powders, nano-coatings, pigments, research & development for nano-particles, ... |
Measuring principle | Mie Scattering Theory according ISO 13320 |
Measuring range | 0.01 μm - 5000 μm |
Type of analysis | dry and wet analysis |
Measuring time | ~ 5 seconds (from start of measurement to display of data) ~ 1 minute (from dispersion liquid filling to measurement and rinse) |
Measuring methods | manual flow cell measurement manual fraction cell measurement (fraction cell and cell holder optional) dry measurement (PowderJet dry feeder optional) |
Required sample amount* | 10 mg - 5 g (for flow cell measurement; depending on feed material) |
Filling quantity | flow cell: 180 - 290 ml, in 4 steps adjustable fraction cell: ~ 15 ml or ~ 10ml LitreFlow: ~ 1000ml Miniflow: ~ 35 - 55ml |
Dispersion liquid | water, alcohol and other organic solvents |
Optical system | inverse fourier-optics |
- Light Source | 655 nm laser diode, 5 mW 405 nm LED, 3 mW |
- Detector | 64-division ring shaped detector (forward direction) 23 separate wide-angle detectors (side and reverse direction) |
Sample circulation system | |
- Ultrasonic chamber | probe: 130 W, 28 kHz |
- Discharge volume | 10 l/min, 15-step speed selection |
- Automatic filling pump | 10 l/min (included) |
- Sample flow cell | tempax glass |
Operating environment | 15 °C - 30 °C, less than 85% rel. Humidity |
Power supply | 100/120/230 V, 50/60 Hz, 300 VA |
Dimensions (W x H x D) | ~ 705 x 500 x 530 mm |
Weight (Measuring unit) | ~ 80 kg (without Dry Powder Jet) |
Interface | USB 2.0 (between PC and Analyzer) |
Operating unit | operating and evaluation software in German, English, French for PC with Windows XP |
Options and Accessories | |
- Dry dispersion unit | yes |
- Fraction cell | tempax glass, 5 ml |
- Micro-quantity dispersion unit | resistent to organic solvents, 50 ml |
- Circulation system | resistent to organic solvents, 180 - 290 ml |
- Autosampler | for 24 samples |
Please note: *depending on feed material and instrument configuration/settings |
Function Principle
The good results for measurements in the sub-micron range are mainly based on the fact that with very fine particles the strong, blue LED light source ensures a clear signal with large scattering angles. These signals are recorded by the innovative 4-channel detectors with increased sensitivity and an extremely high reading frequency of 5,000 values per second. This makes it possible to measure many new materials in the nanometre range which up to now required other methods such as photon correlation spectroscopy (PCS). This is a clear advantage for the user because the analytical performance in combination with a wide measuring range can, in certain circumstances, save the expenditure for a further particle analyser.
The optical layout of LA-960 uses a light path that is about 4 times the length of that of conventional devices. By extending the light path, the signal/noise ratio was considerably improved.
Thanks to the reverse Fourier optics and the light path folded by mirrors, a very compact design size was realized. A newly developed segmented multi-element detector with special arrangement and increased sensitivity of the individual detectors allows the light diffracted at a small angle by large particles to be accuray recorded.
The effectiveness of these new developments is exemplified by the very high resolution of LA-960. For example, it is possible when measuring a multi-modal distribution to resolve five separate modes. Three of these modes can be within a single decade.
Retsch Technology offers high quality optical systems for the characterization of particle size and particle shape. These systems are used in various industries for production and quality control as well as in R&D. Retsch Technology particle analyzers use different measuring principles and cover a size range from 0.3 nm to 30 mm.
All systems feature new innovative technologies and set standards in their product segments. Customer requirements are taken seriously and often find their way into hard- and software upgrades and developments. The systems are suitable for automated and online operation thus fulfilling the increasing requirements of analysis and process engineering.
Contact us
Generate brochure
The CAMSIZER P4 is a compact laboratory instrument for simultaneous measurement of particle size distribution, particle shape and additional parameters of powders and granules.Based on dynamic image analysis by the unique,patented dual-camera technology pourable solids in the range from 20 μm to 30 mm can be measured.
Faster cameras with higher resolution, a brighter light source and improved data processing capabilitiesdifferentiate the CAMSIZER P4 from its predecessors. These improvements increase the measurement speed (~ 1 - 3 minutes); allow more precise shape analysis of small particles and an extended size measurement range.
The extended software functionalities now include animage library containing pictures and contours of each particle and its respective shape and size readings, and a 3-dimensional diagram (3D Cloud scatterplot) of the analysis parameters. New particle shape descriptors allow for analysis of the roundness of particles.
Other well-proven functions like the certified calibration reticle, the automated air flow in the measurement zone, and the motorized funnel height adjustmenthave been preserved in the CAMSIZER P4. These functions provide simple operation, a robust and maintenance-free instrument as well as stable and reliable measurement results even if operated 24/7.
In combination with the optional AutoSampler efficiency can be increased by high sample throughput due to the automated sample measurement.
For online applications the CAMSIZER P4 is available in an online version.
Product Advantages
Features
Application examples1 | abrasives, carbon products, catalysts, coffee, fertilizers, foodstuffs, glass / ceramics, metal powders, pelletized carbon black, pharmaceutical materials, plastics, polystyrene, |
Application examples2 | refractory products, salts, sand, sugar, ... |
Measuring principle | Dynamic Image Analysis (ISO 13322-2) |
Measuring range | 20 μm to 30 mm |
Type of analysis | dry analysis of powders, granulates and bulk materials |
Measuring time | ~ 1 to 3 min (depending on the desired measuring statistics) |
Measuring methods | 60 images/s, each with more than 1.300,000 pixels (corresponds to more than 78 megapixels per second) |
Dimensions (W x H x D) | ~ 850 x 650 x 350 mm |
Weight (Measuring unit) | ~ 40 kg |
Operating unit | PC including operating system, monitor, keyboard and mouse, network card, evaluation software |
Function Principle
The CAMSIZER P4 uses the principle ofdigital image analysis (ISO 13322-2). The sample is transported to the measurement field via a vibratory feeder where the particles drop between a planar light source and two CCD cameras. The projected particle shadows are recorded at a rate of more than 60 images per second and analyzed.In this way almost every single particle in the bulk material flow is recorded and evaluated. Thus, it is possible to measure a wide range of particles from 20 μm to 30 mm extremely accuray, without having to switch measuring ranges or make adjustments.
Thanks to its extremely short exposure times, the novel LED strobe light source allows very sharp images to be produced and distortion-free determination of the projection areas. The sharp contrast allows, at the same time, details of the surface structure of the particles to be seen almost like through a microscope. The frequency of the light flashes is so high that the strobing is not visible to the naked eye.
With the unique, patented dual-camera system a great depth of sharpness, and therefore maximum precision across the entire measuring range, is obtained.The zoom camera provides maximum resolution down to the fine range, while the basic camera also records larger particles and guarantees a high statistical certainty in the results. This ensures the excellent reproducibility of the CAMSIZER measuring results, even if only a relatively small sample amount is available. The results are saved in at least 3,000 size classes.
Subject to technical modifications and errors