尾氣分析儀(液晶)(簡(jiǎn)介: 大屏幕液晶顯示,全中文指導(dǎo)菜單,,可雙怠速,。多組份測(cè)量,每半小時(shí)自動(dòng)提示調(diào)零,,引進(jìn)國(guó)外技術(shù),,進(jìn)口機(jī)芯,自動(dòng)計(jì)算空燃比λ,,內(nèi)置打印機(jī),,RS-232接口可與計(jì)算機(jī)聯(lián)網(wǎng),可測(cè)量油溫,、轉(zhuǎn)速,,尾氣分析儀可以測(cè)量以液化石油氣、壓縮天然氣為燃料的車輛排氣,,汽車尾氣分析儀是3S,、4S站、環(huán)保,、科研機(jī)構(gòu)的產(chǎn)品,。 尾氣分析儀(液晶)(主要技術(shù)性能: 尾氣分析儀(液晶)(、測(cè)量范圍:CO: 0-10.0 10-2(﹪) CO2: 0-20.0 10-2(﹪) HC: 0-10000 10-6(ppm) NO: 0-5000 10-6(ppm) O2: 0-25.0 10-2(﹪) 油溫:18-150℃ 轉(zhuǎn)速:100-20000rpm 2,、尾氣分析儀(液晶)(汽車排放氣體分析儀(液晶)(重復(fù)性誤差: ≤±2﹪ 3,、零點(diǎn)漂移:CO: ±0.06 10-2(﹪)/1h CO2: ±0.5 10-2(﹪)/1h HC: ±30 10-6(ppm)/1h O2: ±0.5 10-2(﹪)/1h NO:±30 10-6(ppm)/1h 4、量距漂移: 不超過示值誤差允許值(1小時(shí)) 5,、示值誤差:CO: ±10﹪ (相對(duì)誤差,,0-10﹪) CO2: ±5﹪ (相對(duì)誤差,0-16﹪) ±10﹪ (相對(duì)誤差,,16.01-20﹪) HC: ±3﹪ (相對(duì)誤差,,0-2000ppm) ±5﹪ (相對(duì)誤差,2001-5000ppm) ±10﹪ (相對(duì)誤差,,5001-10000ppm) NO: ±5﹪ (相對(duì)誤差,,0-4000ppm) ±10﹪ (相對(duì)誤差,4001-5000ppm) O2: ±5﹪ (相對(duì)誤差,,0-25﹪) 油溫: ±2℃ (誤差) 轉(zhuǎn)速: ±1.0﹪ (相對(duì)誤差) 6,、環(huán)境條件:溫度:0℃-40℃ 濕度:≤80﹪ 大氣壓力:60-105kPa 電源:AC 220V±10﹪,; 50Hz 7、預(yù)熱時(shí)間:10min 8,、尾氣分析儀取樣方式: 尾氣:直接取樣,,取樣管長(zhǎng)度5M,取樣探頭長(zhǎng)度900mm,。 油溫:探測(cè)頭插入發(fā)動(dòng)機(jī)潤(rùn)滑油標(biāo)尺孔中,,插入長(zhǎng)度與油標(biāo)尺長(zhǎng)度相同,用橡膠塞堵死,,以防機(jī)油噴出,,導(dǎo)線長(zhǎng)度:5M; 轉(zhuǎn)速:非接觸型測(cè)量方法,,只要靠近汽油發(fā)動(dòng)機(jī)的高壓軟線距離不大于20厘米即可測(cè)定汽油發(fā)動(dòng)機(jī)的轉(zhuǎn)速,。 |