日韩av大片在线观看欧美成人不卡|午夜先锋看片|中国女人18毛片水多|免费xx高潮喷水|国产大片美女av|丰满老熟妇好大bbbbbbbbbbb|人妻上司四区|japanese人妻少妇乱中文|少妇做爰喷水高潮受不了|美女人妻被颜射的视频,亚洲国产精品久久艾草一,俄罗斯6一一11萝裸体自慰,午夜三级理论在线观看无码

產品展廳收藏該商鋪

您好 登錄 注冊

當前位置:
世聯(lián)博研(北京)科技有限公司>供求商機>STB-140,Strexcell-STB-140,Strexcell細胞牽張拉伸系統(tǒng),b-bridge細胞牽張拉伸系統(tǒng)
STB-140,Strexcell-STB-140,Strexcell細胞牽張拉伸系統(tǒng),b-bridge細胞牽張拉伸系統(tǒng)
返回列表頁
  • STB-140,Strexcell-STB-140,Strexcell細胞牽張拉伸系統(tǒng),b-bridge細胞牽張拉伸系統(tǒng)

舉報
貨物所在地: 北京北京市
更新時間: 2025-04-01 21:00:08
期: 2025年4月1日--2025年10月1日
已獲點擊: 196
在線詢價收藏產品

(聯(lián)系我們,請說明是在 化工儀器網(wǎng) 上看到的信息,謝謝!)

產品簡介

STB-140,Strexcell細胞牽張拉伸系統(tǒng),b-bridge細胞牽張拉伸系統(tǒng)

詳細介紹

品牌:strexcell(b-bridge)
貨號:STB-CH-04,STB-CH-10,STB-CH-04-XY,STB-CH-4W,STB-CH-04ST-XX,STB-CH-10ST-XX
供應商:世聯(lián)博研(北京)科技有限公司

STREXS是一種模擬細胞生長過程中機械應力的裝置。張力腔室中的細胞被儀器拉伸或壓縮,。施加在細胞上的機械應力更好的模擬了自然動態(tài)生理環(huán)境,,可精準控制施加在細胞上的應力級別。

細胞應力拉伸儀(STREX)的優(yōu)勢

× 精準的應力程序設計

× 高頻率和低頻率處可實現(xiàn)連續(xù)拉伸/壓縮

× 培養(yǎng)腔室所受應力的均一性

× 橫向剪切力非常小

× 操作便捷

 

strexcell細胞拉伸培養(yǎng)腔室 ,strexcell細胞牽拉培養(yǎng)腔室Stretch Chamber,STB-CH-04,STB-CH-10,STB-CH-04-XY,STB-CH-4W,STB-CH-04ST-XX chamber stands,STB-CH-10ST-XX chamber stands

 

型號

項目

ST-140-04

ST-140-10

ST-150

ST-190-XY

應用范圍

? 細胞骨架重組

? 細胞形態(tài)學

? 基因或蛋白表達

? 信號傳導

? 長期性研究(幾小時到幾天)

? 細胞骨架重組

? 細胞形態(tài)學

? 離子調控

? 鈣離子流入

? 氮氧化合物的合成

? 培養(yǎng)過程的實時監(jiān)測

? 短時間的過程研究(15-20min)

腔室數(shù)目

6

5

1

1

腔室大小—培養(yǎng)面積

4cm2

10cm2

4cm2

4cm2

應力方向

單軸拉伸

單軸拉伸

單軸拉伸

雙軸拉伸/壓縮

與顯微鏡兼容性

-

-

兼容Nikon, Olympus, 可選Zeiss, Leica

兼容Nikon, Olympus, 可選Zeiss, Leica

培養(yǎng)箱

標準培養(yǎng)箱

標準培養(yǎng)箱

標準培養(yǎng)箱

標準培養(yǎng)箱

程序個數(shù)

64

64

64

64

The exceptional physical and chemical properties of the silicone elastomer PDMS (polydimethylsiloxane) create a specially flexible thin-membrane chamber.

● High Reproducability:
Springy PDMS chambers bounce back from stretching and compression with their original properties intact. Thus, the chambers demonstrate good reproducibility in applications requiring continuous mechanical stretching over prolonged periods.

● Superior Transparency:
An optically transparent, ultra-thin (100-200 µm) membrane at the well bottom not only makes stretch chambers compatible with optical microscopy techniques, but with fluorescence detection and microscopy as well.

Uniformity of direction and force are issues of crucial concern in cell stretching. Stretching systems and chambers with insufficient properties can cause extraneous stretching on the wrong axis and generate a secondary load in that direction. In addition, these systems may not apply stress equally to all cells in the chamber, making it impossible to accuray gauge the effect of the stretch stimulus across the unevenly treated sample.

The STREX Cell Stretching System is designed to achieve stretching in a single, parallel direction, with only a very weak secondary load. Research has demonstrated that the STREX system enables highly reproducible cyclic stretching over prolonged periods at ratios of 1-20%.(Ref)

Because the methyl groups align themselves to the surface, the stretch chamber is highly water-repellent, meaning that cells will not adhere without pre-treatment of the chamber. Thus, the PDMS chamber surface needs to be coated with extracellular matrix in order to successfully adhere and culture cells. Fibronectin, collagen, gelatin and laminin, among others, can be used for this purpose.

STREX offers standard stretch chambers in two sizes, the 4cm² and 10cm² models. Specialized versions are also available, including multi-well, gel-stretching, and transwell experiment chambers.

(Ref) Naruse, K., Yamada, T., Sai, X.R., Hamaguchi, M., Sokabe, M. Pp125FAK is required for stretch dependent morphological response of endothelial cells. Oncogene 1998, 17:455-463.

Stretch Chambers

 

 

STB-CH-04 Effective size:2.0×2.0×1.0cm
 

Compatible with

STB-10-04

STB-140-04

STB-150

STB-195

Catalog No.

STB-CH-04

 Item name

4cm² chamber (10 pcs.)/1 set

  

 

STB-CH-10 Effective size: 3.2×3.2×1.0cm
 

Compatible with

STB-10-10

STB-140-10

Catalog No.

STB-CH-10

 Item name

10cm² chamber (5 pcs.)/1 set

  

 

STB-CH-04-XY

Compatible with

XY-biaxial stretching Effective size: 2.0×2.0×1.0cm

 

Compatible with

STB-190-XY

Catalog No.

STB-CH-04-XY

 Item name

4cm² XY chamber (5 pcs.)/1 set

  

 

STB-CH-4W multiwell type Effective size: 1.5×1.5×1.0cm 
 

Compatible with

STB-10-10

STB-140-10

Catalog No.

STB-CH-4W

 Item name

10cm² chamber with 4-wells (5 pcs.)/1 set

  

Note: Chamber specifications:

Heatproof temperature: 5℃-180℃, Humidity: 20-100%
Durability: 900,000cycles approx. (when stretching ratio=20%)

Note: Store unused chambers in a cool dark place. Chambers are denatured by UV-rays irradiation.

Chamber Stands

 

STB-CH-04ST-XX chamber stands
Note: "XX" denotes stretching ratio. ex)STB-CH-10ST-05: for use with 5% stretching ratio
Stretching stands for STB-CH-04.0

 

Compatible with

holds 1 chamber,

STB-CH-04

Catalog No.

STB-CH-04ST-XX

 Item name

stands for 4cm² chambers

 Price

Please contact us

 

STB-CH-10ST-XX chamber stands
Note: "XX" denotes stretching ratio. ex)STB-CH-10ST-05: for use with 5% stretching ratio
Stretching stands for STB-CH-10.0

 

Compatible with

holds 1 chamber,

STB-CH-10

Catalog No.

STB-CH-10ST-XX

 Item name

Stands for 10cm² chambers

 Price

Please contact us

Coating Protocols for Stretch Chambers

Stretch chambers as sold are not sterile and provide no cell adhesion. Therefore, the chamber must first be autoclaved for 20 minutes at 121° C, and then the membrane must be coated with extracellular matrix before seeding cells.

Coating protocol: Fibronectin

  1. Prepare a fibronectin solution by dissolving 0.05 mg/ml of fibronectin in PBS.
  2. Place the stretch chamber in a culture dish and pour the fibronectin solution into the chamber well so that it compley covers the bottom surface.
  3. Incubate the fibronectin-treated chamber in the culture dish at 37° C for at least four hours.
  4. Remove the culture dish from incubator, and draw up any remaining solution from the chamber using a pipette or other suitable device.

Coating Protocol: Collagen

  1. Prepare and autoclave a dilution of hydrochloric acid (pH3.0, 1mM).
  2. Dilute type 1 collagen in the autoclaved hydrochloric acid.
  3. Place the stretch chamber in a culture dish and pour the collagen solution into the chamber well so that it compley covers the bottom surface.
  4. Cover the culture dish with a lid and incubate at 37° C for at least four hours.
  5. Remove the culture dish from incubator, and leave to stand for a period. Then draw up the remaining solution from the chamber using a pipette or other suitable device.
  6. Rinse the chamber twice with serum-free culture fluid to remove any excess collagen solution that may have remained after the above steps.

Coating protocol: Gelatin

  1. Prepare a gelatin solution by dissolving 2% gelatin powder in PBS. Autoclave the gelatin solution
  2. Place the stretch chamber in a culture dish and pour the gelatin solution into the chamber well so that it compley covers the bottom surface.
  3. Incubate the gelatin-treated chamber in the in the culture dish at 37° C for at least four hours.
  4. Remove the culture dish from incubator, and draw up any remaining solution from the chamber using a pipette or other suitable device.

Protocol of Fluorescent Staining after Stretching

  1. Splice out cell plane from stretch chamber with surgical knife.
    (as large as approx. 0.8×0.5cm)->the size varies according to the size of container to be used since step 2.
    Splicing to make the longer side get along with the stretching direction makes it easy to find out the stretching direction afterwards.
  2. put the membrane spliced in step 1 into the container with PBS(‐).
    (using 1×1 chamber(without frame) attached on a cover glass.) 
  3. PBS(‐) wash, 2 times 
  4. fix with 4% formalin solution in PBS(‐)->RT, 5 min, shake
  5. PBS(‐) wash, RT, 5 min, 3 times 
  6. 0.1% TritonX-100 in PBS(‐), pierce cell membrane->RT, 5 min, shake
  7. PBS(-) wash->RT, 5 min, 3 times 
  8. block 2% BSA in PBS(‐)->RT, 30 min, shake
  9. primary antibody in 0.1%Tween20 in PBS(‐)->RT, 30min, shake
  10. 0.1%Tween20 in PBS(‐) wash->RT, 5 min, 3 times
  11. secondary antibody in 0.1%Tween20 in PBS(‐)->RT, 30 min, shake
  12. 0.1%Tween20 in PBS(‐) wash->RT, 5 min, 3 times
  13. put on a slide glass to enclose(Perma Fluor)->put the cell membrane side down
  14. Fluorescent observation

Cells Stretching System

Manual Stretch System(for trials) STB-10

Stretching culture system of manual type

Conduct stretching/compression manually. Please use this system for evaluation purpose of automatic stretching systems(e.g. STB-140) before installation.
Users can share the chambers with STB-140.
Two models available in accordance with chamber sizes.

 System Configuration System Specification
STB-10-04(for 4cm²)
STB-10-10(for 10cm²)
Stretching ratio:
up to 20%, 0.5mm stretching a turn of the dial(2.5% of stretching ratio for STB-10-04, 1.6% for STB-10-10).
Note: Conduct culture putting the system into a culture dish.

Stimulation direction: uniaxial

Automatic Stretch System STB-140

Standard system with high versatility

The system has functionality to load stretching stimulation on cells while culturing them in CO² incubator.
● Functionality to stimulate multiple chambers simultaneously makes it easy to compare between samples.
● Install the main unit within CO² incubator, the controller outside.
● Stretch chamber mounting unit is removable, so users put it into clean bench and conduct aseptic work.
Preprogrammed one-chip microcomputer is embedded in the controller. While operation, users choose the stretching ratio and stretching frequency with DIP switch on the controller, and make the main unit to generate the desired stretching pattern.
The controller also has the functionality to control the water flow for refrigeration of the motor in the main unit.

 System Configuration System Specification
Main Unit of Stretching System: 
STB-140-04(for 4cm²)
STB-140-10(for 10cm²)
STB-140-4*10(both for 4cm²/10cm²)
Control Unit:
Controls stretching patterns and refrigeration of the motor.
Cables:
The main unit and the controller are connected with the composite cable of signal cable and coolant cable(for the motor in the main unit).
Coolant tank, Coolant tube
STB-140-04:
4cm² chambers up to 8 units
STB-140-10:
10cm² chambers up to 6 units
STB-140-4*10:
4cm² chambers up to 4 units
10cm² chambers up to 5 units
Stretch chamber mounting unit is removable.
(can be put a lid on with a culture dish)
Stretching patterns: up to 64 patterns
Stimulation direction: uniaxial
Stretching ratio: up to 20%
Driver(4.6kg)
W270 × D350 × H130mm
Controller(3.5kg)
W320 × D220 × H125mm
※AC100V-240V 75W

Stretch System for Microscopes STB-150

Installable on microscope stage

Enables to observe morphological changes and ionic behavior in real time, under stretching stimulation.
Install the main unit of the stretching system on microscope stages to load automatic stretching stimulation with the controller.

 System Configuration System Specification
Main unit: normal type is compatible with Nikon, Olympus(compatibility with Zeiss and Leica is optional)
Controlling unit: controls stretching patterns.
Compatible with 4cm² chamber
Stimulation direction: uniaxial
Stretching patterns: up to 64 patterns
Stretching Stimulation Loading is up to 20 minutes continuously.
(The system is without motor refrigeration unit. Long period operation results in the overheat of the motor. Use STB-140 for long period, continuous stimulation loading.)

Stretch System for Microscopes STB-190-XY

Installable on microscope stages with functionality of biaxial stretching/compression

 

 System Specification
Compatible with 4cm² XY chamber

Stimulation direction: XY biaxial, compatible with uniaxial stimulation

Stretching patterns: up to 64 patterns

Stretching Stimulation Loading is up to 20 minutes continuously.
(The system is without motor refrigeration unit. Long period operation results in the overheat of the motor. Use STB-140 for long period, continuous stimulation loading.)

Extention System for Microscopes(with Microincubator) STB-195

Installable on Microscope Stage(with Microincubator)

STB-150 equipped with Microincubator

 System Configuration System Specification
Gas cylinder(Air 95% + CO² 5%) requiredTemperature: 37℃
Humidity: Saturated humidity

Accessories for Cultured Cells Stretch Systems

Culture Fluid Automatic Reflux System(Accessory for STB-140)SBB-100

Conducts full automatic replenishment and replacement of culture fluid while long-term Stretching Culture in CO² incubator

The system enables long-term culture under stretching stimulation. Newly-developed multi-channel bulb unit enables replenishment and draining culture fluid for all stretch chambers to keep liquid surface of culture fluid in those chambers.
Tubes and cables can be centrally let out from rubber plug for utility on the back of incubator so that the controllability on the front of incubator will not be compromised.

 System Configuration System Specification
Controller
Multi-channel bulb unit
Replenishment pump for culture fluid(optional), Drain pump for culture fluid(optional)
Time and Volume of replenishment of culture fluid can be set up to 64 patterns with the controller.

Electric Stimulation Synchronization Unit(Accessory for STB-140-10) SDB-50

Combined with STB-140-10, it loads stretching stimulation on cells synchronizing with electric stimulation.

 

 System Configuration System Specification
Electrode lid
Synchronization unit Note: electric stimulation amplifier(not included with the system) is required.
Stimulation frequency: 1-60cycles/min
Stimulation duration: any durations(one-time stimulation to periodic stimulation for a month)
Stretching ratio: up to 20%
Stretching stimulation direction: uniaxial
Stretchs up to 6 10cm² chambers once.

收藏該商鋪

登錄 后再收藏

提示

您的留言已提交成功,!我們將在第一時間回復您~

對比框

產品對比 產品對比 聯(lián)系電話 二維碼 意見反饋 在線交流

掃一掃訪問手機商鋪
86-010-67529703
在線留言