日韩av大片在线观看欧美成人不卡|午夜先锋看片|中国女人18毛片水多|免费xx高潮喷水|国产大片美女av|丰满老熟妇好大bbbbbbbbbbb|人妻上司四区|japanese人妻少妇乱中文|少妇做爰喷水高潮受不了|美女人妻被颜射的视频,亚洲国产精品久久艾草一,俄罗斯6一一11萝裸体自慰,午夜三级理论在线观看无码

官方微信|手機(jī)版

產(chǎn)品展廳

產(chǎn)品求購(gòu)企業(yè)資訊會(huì)展

發(fā)布詢價(jià)單

化工儀器網(wǎng)>產(chǎn)品展廳>分析儀器>電化學(xué)分析儀>其它電化學(xué)儀> 6010101

6010101

具體成交價(jià)以合同協(xié)議為準(zhǔn)
產(chǎn)品標(biāo)簽

6010101

聯(lián)系方式:賀經(jīng)理查看聯(lián)系方式

聯(lián)系我們時(shí)請(qǐng)說(shuō)明是化工儀器網(wǎng)上看到的信息,謝謝!


上海鉑勒機(jī)電設(shè)備有限公司擁有強(qiáng)大的實(shí)驗(yàn)室儀器供應(yīng)鏈,,致力于升級(jí)中國(guó)各級(jí)實(shí)驗(yàn)室的儀器設(shè)備,。提高中國(guó)各級(jí)實(shí)驗(yàn)室的科研水平。

專業(yè)的技術(shù)團(tuán)隊(duì)為我們的客戶提供便捷的一站式采購(gòu)服務(wù),,作為500強(qiáng)信賴的合作伙伴相信一定會(huì)成為閣下Z明智的選擇,。

鉑勒機(jī)電將珍視每一位客戶,關(guān)注每一位客戶的感受,,穩(wěn)健務(wù)實(shí),,執(zhí)著于服務(wù)與品質(zhì),與尊敬的客戶,、合作伙伴及員工共贏,。
現(xiàn)在就致電鉑勒機(jī)電,我們值得閣下信賴,。

企業(yè)宗旨:

為的實(shí)驗(yàn)室用戶提供高性價(jià)比的設(shè)備和Z滿意的服務(wù),,將企業(yè)塑造為化企業(yè)!

企業(yè)文化:

倡導(dǎo)以人為本,、科學(xué)管理,,致力于與員工共同成長(zhǎng)!

提倡勤奮工作、提倡協(xié)作,、交流的團(tuán)隊(duì)精神,!

欣賞并鼓勵(lì)發(fā)揮員工個(gè)人的聰明才智及創(chuàng)新精神 ;


Your Lab, Our Service



哈希DR900,,哈希DR890,,哈希HQ30D,哈希DR3900,,哈希2100Q,,哈希2100N,哈希試劑,,Nalgene耗材,,Brand耗材,PFA試劑瓶

Simplicity

A simplified two-module design includes the sensor and the controller interface. The controller accepts two turbidity sensors€”adding a second 1720E sensor makes a system with two complete turbidimeters. Connections are simple plug & play.

Data Collection and Display

The 1720E Turbidimeter uses the sc200 Controller to receive data from up to two sensors. A built-in data logger collects turbidity measurement at user selectable intervals (1-15 minutes), along with calibration and verification points, alarm history, and instrument setup changes for 6 months. Communications using MODBUS®/RS485, MODBUS®/RS232, LonWorks® protocols or the wireless IR port are available. The sc200 Controller is also compatible with AquaTrend® Networks. Local display, recall, graphing, and trending in CSV format make chart recorders redundant.

USEPA Reporting

Meets and exceeds USEPA Method 180.1 for measuring turbidity for drinking water compliance. One controller accepts up to two plug and play sensors giving you two complete turbidimeters. Sensitive to fine changes in low level turbidity with a built-in bubble removal system. Built-in datalogger stores up to 6 months of data. Versatile digital output-MODBUS protocol, LonWorks or wireless IR port. Two year warranty.

Experience

The 1720E Turbidimeter reflects 45 years of Hach leadership in turbidity measurement science. Hach has the largest turbidimeter installation base in the world. And, Hach offers a two-year warranty on the 1720E.

What's in the box

1720E, 1720E User Manual, and 1000 mL 20 NTU StablCal ®.

Specifications

Accuracy:(Defined according to ISO 15839.
±2% of reading or ±0.015 NTU (whichever is greater) from 0 to 40 NTU ; ±5% of reading from 40 to 100 NTU

Accuracy 2:±5% of reading from 40 to 100 NTU

Alarm:Three set-point alarms, each equipped with an SPDT relay with unpowered contacts rated 5A resistive load at 230 Vac; built into the sc200 Controller

Certifications:Listed by ETL to UL 61010A-1: Certified by ETL to CSA C22.2 No. 1010.1: CE certified by Hach Company to EN 61010-1

Communication:Network card compatible; MODBUS®/RS485, MODBUS/RS232, PROFIBUS, HART

Compliance:Standard Methods 2130B, USEPA 180.1, Hach Method 8195

Dimensions (H x W x D):10 in x 12 in x 16 in (254 mm x 305 mm x 406 mm)

Drain Fitting:1/2 NPT female, 1/2 hose barb (provided)

Enclosure Rating:NEMA 4X/IP66

Flow Rate:Sample Inlet Fitting: 1/4 NPT f, 1/4 compression fitting (provided)

Number of Alarms:Three set-point alarms, each equipped with an SPDT relay with unpowered contacts rated 5A resistive load at 230 Vac; built into the sc100 Controller

Operating Humidity:5 to 95 % non-condensing

Operating Temperature Range:0 to 40 °C (Double Sensor System)

Outputs:Recorder Two selectable for 0-20 mA or 4-20 mA; output span programmable over any portion of the 0-100 NTU range; built into the sc100 Controller

Power Requirements (Hz):50 - 60 Hz

Power Requirements (Voltage):100 - 230 V AC

Range:0.001 to 100 Nephelometric Turbidity Units (NTU)

Repeatability:(Defined according to ISO 15839.)
Better than ± 1.0 % of reading or ±0.002 NTU, whichever is greater

Response Time:Initial response in 1 minute, 15 seconds for a full-scale step change

Sample Flow Rate:200 to 750 mL/minute (3.1 to 11.9 gal/hour)

Sample Temperature:0 to 50 °C (32 to 122 °F)

Shipping Weight:1720E Turbidimeter and sc100 Controller: 
6.12 kg (13.5 lbs.)

Signal average time:User selectable from 6, 30, 60, 90 seconds; default 30 seconds

Storage Conditions:-20 °C to 60 °C

- See more at: http://www.hach.com/1720e-low-range-process-turbidimeter-turbidity-sensor-only/product-details?id=7640457219&callback=qs#sthash.p47wIYLN.dpuf