美國(guó)CCS壓力開關(guān)
2008-04-10招商項(xiàng)目介紹
Compact Pressure Switches | |
| 6900 Series- Standard Switch Features |
![]() | Pressure Series: 6900G, 6900GZ, 6900P - Wide Range DiaphragmPiston. Pressure 1 to 6500 psi. Standard Features: • NEMA 4, 13 • Weatherproof, • 6900 only—CSA Certified enclosure 4 non-hazardous locations File LR22665 , Ambient Temp. Range: -30°F to +160°F or -34°C to +71°C. |
![]() | Pressure Series: 6901G, 6901GZ, 6901P - Wide Range DiaphragmPiston. Pressure 1 to 6500 psi. Standard Features: • NEMA 4, 13 • Weatherproof, • 6900 only—CSA Certified enclosure 4 non-hazardous locations File LR22665 , Ambient Temp. Range: -30°F to +160°F or -34°C to +71°C. |
![]()
| Pressure Series: 6900GE6900PE - Wide Range DiaphragmPiston. |
![]() | Pressure Series: 6900GZE6900GZE-7042 - Wide Range Diaphragm, SST PortSST Construction. Pressure 1 to 2500 psi. Standard Features: •U.L./CSA Explosion Proof: Div. 1, 2. Div. 1 explosion-proofhermetically sealed electrical assembly P/N 46-1058 46-1061 for "M" model option, listed by both Underwriter’s Laboratories, Inc. File No. E32961CSA Testing Laboratories File No. 22921 for hazardous locations, Class 1, Groups A, B, C,D; Class 2 Groups E, F,G. •NEMA 4, 7, 9, 13. Ambient Temp. Range: -30°F to +160°F or -34°C to +71°C. |
![]() | Pressure Series: 6900GZE*-70666900GZE*-7074 - Wide Range DiaphragmFlush Mount. Pressure 1 to 2500 psi. Standard Features: •U.L./CSA Explosion Proof: Div. 1, 2. Div. 1 explosion-proofhermetically sealed electrical assembly P/N 46-1058 46-1061 for "M" model option, listed by both Underwriter’s Laboratories, Inc. File No. E32961CSA Testing Laboratories File No. 22921 for hazardous locations, Class 1, Groups A, B, C,D; Class 2 Groups E, F,G. •NEMA 4, 7, 9, 13. Ambient Temp. Range: -30°F to +160°F or -34°C to +71°C. |
![]() | Pressure Series: 6900DZE - Low/Mid Range Diaphragm SST Port. Differential Pressure 0.4 to 75 psid. Standard Features: •U.L./CSA Explosion Proof: Div. 1, 2. Div. 1 explosion-proofhermetically sealed electrical assembly P/N 46-1058 46-1061 for "M" model option, listed by both Underwriter’s Laboratories, Inc. File No. E32961CSA Testing Laboratories File No. 22921 for hazardous locations, Class 1, Groups A, B, C,D; Class 2 Groups E, F,G. •NEMA 4, 7, 9, 13. Ambient Temp. Range: -30°F to +160°F or -34°C to +71°C. |
![]() | Pressure Series: 611G, 611GE611V, 611VE - Low Range Diaphragm. |
![]() | Pressure Series: 611GZE*8100 - Low Range DiaphragmSST Construction Pressure 1 to 180 psi. Standard Features: • U.L./CSA Explosion Proof: Div. 1, 2 Div. 1 explosion-proofhermetically sealed electrical assembly P/N 46-1058 46-1061 for "M" model option, listed by both Underwriter’s Laboratories, Inc. File No. E32961CSA Testing Laboratories File No. 22921 for hazardous locations, Class 1, Groups A, B, C,D; Class 2 Groups E, F,G. • NEMA 4, 7, 9, 13. • Weatherproof. Ambient Temp. Range: -30°F to +160°F or -34°C to +71°C. |